Products

+
  • 图片(1758680213515).jpg

ADSS-SS-80M

Product Category:


Relying on more than 10 yea of experience in the production of communications industry products in the Cixi factory, Ningbo Huitong communication Co., Ltd. can provide different kinds of professional Fiber optic distribution box , Joint closure , Fiber optic cross connection cabinet ,Network cabinets and ODF cabinets.

Keywords:

OUTDOOR CABLE

Product Details

Until now, we have provided services to more than 20 world-renowned telecom operators and enterprises, such as China Telecom, China Mobile, Malaysia Telecom, etc.
 

In the new year of 2022, Huitong Communication will focus on the design and developing of new fiber optic distribution box and joint closure , Increase investment in research and development, provide more professional products and services to customers in the communications industry around the world.

ADSS Cable Span 80m (FTTX)

All dielectric, self-supporting cable, suitable for outside plant use in aerial installations.

 

Dimension and descriptions

Item

Contents

Value

6

12

24

36

48

72

96

144

Structure

Type

1+6

1+5

1+6

1+8

1+12

Loose tube

Fiber counts/tube

6

12

12

12

12

Outer diameter (mm)

1.8

2.2

2.2

2.2

2.2

Central

Material

FRP

strength member

Diameter (mm)

1.8

1.8

2.4

2.8

3.5

PE layer diameter

(mm)

/

/

/

3.7

6.8

Water blocking

Material

Water blocking yarn & tape

Peripheral

strength member

Material

Aramid yarn

Outer Sheath

Material

HDPE

Color

Black

Thickness (mm)

Nominal: 1.5

Ripcord

Number

2

Color

Red

Cable diameter(mm) Approx.

9.1

9.4

10.0

11.2

14.4

Cable weight(kg/km) Approx.

65

70

65

80

100

160

Max allowable tension(N)

1200

1250

1500

1800

2500

Crush(N/100mm)

1500

750

 

Cross section of cable

 

 

Referential image

 

Fiber and loose tube identification

The color code of the optical fibers and the loose tubes responds to the EIA-TIA 598-A specification, as detailed:

 

Optical Fiber

Parameter

Speciication

MFD (1310nm)

8.7~9.6 um

Cladding diameter

125±1.0um

Fiber diameter

235~255um, with UV coating, and colored to : 250±15um

Core/cladding concentricity error

≤ 0.6um

Coating/cladding concentricity error

≤ 12.0um

Cladding non circularity

≤ 1.0%

Cut of wavelength

λcc ≤ 1260nm

Attenuation coeicient

1310nm: 0.35dB/km max aier cabling

1550nm: 0.21dB/km max aier cabling

Bending-loss performance of   opticaliber @1310nm&1550nm

≤ 0.05dB (100 turns around a mandrel

of 50mm diameter)

Polarization mode dispersion maximum individual ibre

≤ 0.2ps/vkm

Polarization mode dispersion link

value

≤ 0.1ps/vkm

Zero-dispersion wavelength

1300~1324nm

Zero-dispersion slope

≤ 0.092ps/nm²·km

 

Application

Item

Value

Max. pole distance

80m

Opera on temperature

-40 ºC ~ +70 ºC

Storage temperature

-40 ºC ~ +70 ºC

Static bending radius

10 times the cable diameter

Dynamic bending radius

20 times the cable diameter

 

Mechanical. Physical and Envionmental Test Characteristics@ 1550nm

Items

Test Method

Requirements

Tension

IEC 60794-1-21-E1

Load: According to 3.5

Sample length: Not less than 50m.

Duraion ime: 1min.

Addiional a enuaion:

≤ 0.05dB aier test

No damage to outer jacket

and inner elements

Crush

IEC 60794- 1-21-E3A

Load: According to 3.5

Duraion of load: 1min

Addiional a enuaion:

≤ 0.05dB aier test

No damage to outer jacket

and inner elements

Impact

IEC 60794-1-21-E4

Radius: 300 mm

Impact energy: 10J

Impact number: 1

Impact points: 3

Addiional a enuaion:

≤ 0.05dB aier test

No damage to outer jacket

and inner elements

 

Items

Test Method

Requirements

Repeated

bending

IEC 60794-1-21-E1

Load: According to 3.5

Sample length: Not less than 50m.

Duraion ime: 1min.

Addiional a enuaion:

≤ 0.05dB aier test

No damage to outer jacket

and inner elements

Torsion

IEC 60794- 1-21-E3A

Load: According to 3.5

Duraion of load: 1min

Addiional a enuaion:

≤ 0.05dB aier test

No damage to outer jacket

and inner elements

Water

Penetraion

IEC 60794-1-22-F5B

Time : 24 hours

Sample length : 3m

Water height : 1m

No water leakage.

Temperature cycling

IEC 60794-1-22-F1

Sample length: at least 1000m

Temperature range:-40 ºC~+70 ºC

Cycles:2

Temperature cycling test dwell ime:

12 hours

The change in a enuaion

coefficient shall be less

than

0.05 dB/km.

Other parameters

According to IEC 60794-1

 

Related Products

FTB-08C

Capacity: 8 cores Material: ABS/PC+ABS Dimension,W*H*D(mm): 249*203*53 Inlets/Outlets: 2+8&3+8 Accessible Cable Diameter: ∅8-∅12mm Protection Level: IP65 Input Cable Method: Cutting /Uncutting PLC Splitter: Tube &module type

FTB-08C-3

Capacity: 8 cores Material: ABS/PC+ABS Dimension,W*H*D(mm): 249*203*53 Inlets/Outlets: 2/8 Accessible Cable Diameter: ∅8-∅12mm Protection Level: P65 Input Cable Method: Cutting/Uncutting PLC Splitter: Tube type

FTB-08F-1

Capacity: 8 cores Material: PC/PC+ABS Dimension,W*H*D(mm): 210*112*92 InlotsIOutlet: 1-8 Protection Level: IP68 InputCable Method: Cutting/Pre connected Optical Cable PLC Splitter Type: 1:8 Tube Splitter Adapter Type: OptiTap Adapte

FTB-08F-2

Capacity: 8 cores Material: ABS/PC+ABS Dimension,W*H*D(mm): 268*202*82 Inlets/Outlets: 2/12 Accessible Cable Diameter: ∅8-∅12mm Protection Level: P65 Input Cable Method: Cutting /Uncutting PIC Splitter: Tube 8 module type

Online Message

If you are interested in our products, please leave us a message, and we will contact you as soon as possible!

%{tishi_zhanwei}%

Online Message

If you are interested in our products, please leave us a message, and we will contact you as soon as possible!

%{tishi_zhanwei}%